You should get a pool chemical test from a pool shop to confirm your salinity level. If your filter is dirty it could reduce flow. • Add the right amount of salt according to the chart in your manual. If the flow light is red, that means the water flow is too low to operate properly. Number of swimmers has increased: Increase the daily operating time of the chlorinator. YES NO Chlorinator is working properly. Insufficient operating time of the saltwater chlorinator: Increase the daily operating time of the saltwater chlorinator. More . The chlorine output goes up to two bars but no more and there doesn't appear to be any chlorine in the output water. Check that the 120/230V power supply is … Does cell model / size match power pack? There is a slit on each and I carefully used a blunt knife to open each one a little so that the connections sit firm on each one. A salt chlorinator cell not working causes the water to become murky and dirty with time and most sane people wouldn’t touch it with a ten foot pole. They will advise if salt actually needs to be added and how much you need to add. Post by Strannik-au » Sat 19 Jul, 2008 19:40 . You add salt directly to the pool water—the Intex system does not have a salt reservoir. TROUBLESHOOTING GUIDE – SALT CHLORINATORS No LED lights are lit There may be numerous reasons why the salt chlorinator LED does not light. (see Cell pg. YES NO 3. Is unit wired 220V? Just like any other salt chlorine generator, the Aqua Rite may need a quick ‘tune up’ from time to time. Nothing else loses voltage so I jumped 12 volts to the cells voltage terminal and presto The unit is making chlorine. The action of the brine passing over the cell creates gaseous activity. If the light ‘no flow’ is written on your salt chlorinator, then it may indicate less flow of water passing. I have cleaned the new cell and that doesn't seem to help. Why does my salt chlorinator say no flow? As always, if you need any help or advice why not call in and see us at our store in Rocklea or give us a call on 07 3277 2554. Pool chlorinators eliminate the daily chore of manually measuring and adding chlorine to a swimming pool. 4. My check system light is on and despite adding a lot of salt my reading is still saying very low salt and stuck at 2200 ppm. These quick and easy tips should ensure you avoid the most common salt water chlorinator problems. AutoPilot’s industry leading salt water pool systems turn ordinary salt into a self-regenerating supply of pure chlorine for pool and spa water that’s clean, clear and luxuriously soft. 1. So I am here to tell you, most likely the answer is an emphatic "No". I have no chlorine in the pool for about a week. Run time of your salt chlorinator can also increase scale build-up on your salt cell. If you had no luck after cleaning your media filter Try turning the pump off and setting your filter to recirculate. The “No Flow” light indicates that the flow switch is not detecting sufficient water passing through. I have a Zodiac LM2 series chlorinator. I have added fresh water to try to reduce salt level. Check there is 220V incoming power. Corroded plates and other anomalies upon inspection. CHECK FLOW LEVEL - When "NO FLOW" LED is illuminated, the flow switch has detected no water flow and the SCG is NOT generating chlorine. Just last week, the "NO FLOW" light has been on and now the unit does nothing and I have no chlorine in my pool. Cholorine level is testing at about zero. Is something wrong with my salt cell generator?" Fluidra Australia AstralPool 2 weeks ago. A salt chlorinator cannot produce enough chlorine to do this task. After refilling the pool and balancing the PH and salt (now 3000 ppm), chlorinator has stopped working, it shows no flow. ; Salt level in pool water is less than 2,000 ppm: Check the salt level, and adjust as needed. First Name. Hi Scott, Thanks for your inquiry. How to Troubleshoot Swimming Pool Chlorinators. I noticed the salt level is above 3200 ppm after multiple testing and the chlorine levels never change. The unit reported low salt no matter how much salt I dumped into the pool. This issue must be treated manually before a salt chlorinator can operate correctly. More. 9.50 10.00 If salt level is above the range, partially drain pool and/or spa and refill with fresh water to achieve a salt level of 3200ppm. Is salt level 4000 ppm? Top. We’ve provided a list of common causes of no flow that could save you a few hundred dollars in having someone diagnose the issue for you. We had a repair done in the pool and had to drain some H2O out. "No Flow" LED illuminated. Why is my Salt Generator Flashing ‘Inspect Cell’? Insufficient operating time of the saltwater chlorinator: Increase the daily operating time of the saltwater chlorinator. Cell may be nearing the end of its life. Why Are There Air Bubbles Flowing Into The Pool From The Return Fitting(s)? Algae is the most common cause of low or zero chlorine levels. Turn it off or leave it alone? If the water is clear, it’s not creating chlorine. Some of the most experienced problems with Pentair IC40 include: 1. Life Light Flashing. Share. Chlorinated water leaves the canister in a hose that connects to the main return line after the filter. If you now have normal flow, try backwashing again, if it still doesn’t work you may be due for a media change. When the flow monitor indicates “NO FLOW” in spite of water moving through the cell. As always, if you need any help or advice why not call in and see us at our store in … The cell is about 13 months old. The “No Flow” light indicates that the flow switch is not detecting sufficient water passing through. This is due to the chlorinator cell building up scale on the electrical plates. YES NO Add salt to compensate. • In this case either the Flow Switch is defective of you have a restriction in the pool system. my goldline control is showing "chlorinator off no flow". Use a cleaning kit designed for salt cells to keep the plates clear of buildup. Replace the flow sensor. Subscribe To Our Newsletter For Regular Pool Chlorinator Tips And Advice . Calcium level was also low so added. 9.50 10.00 If salt level is above the range, partially drain pool and/or spa and refill with fresh water to achieve a salt level of 3200ppm. The cell is about 13 months old. If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. My salt light won't go off but I have tested the level an its around 5,000 ppm. Add salt according to chart in Owner’s Manual. If they are flashing red and green – you have too much salt and need to add water to your pool to dilute the salt. One problem that users have found with Intex saltwater chlorine generators is repetitive Low Salt Level errors – even when salt levels in your water are adequate. YES NO Have qualified electrician wire to 220V. Excessive sun exposure has evaporated chlorine: Use a pool cover when the pool is not in use. You should never let that salt level drop below three thousand parts because it will reduce the life of your electrode. No Flow Check Salt High Salt Inspect Cell Maximum Current (Amps) before shutdown T-Cell 3: 4.15 T-Cell 5: 6.40 T Cell 9: T Cell 15. No Flow usually means there is not enough water crossing across the cell detection terminals in the cell.I had loose terminals on the chlorinator back and to correct this I opened the slitted gaps carefully on each terminals brass like connections. Check the level of salt in your Spa or pool. There has got to be an action – assuming there is enough salt in the pool. Question: The salt level on my display says my pool is at 3900 ppm, and the stick is reading low free chlorine and total chlorine, as well as pH. Had pool water checked recently, slightly low on the salt content so added the usual amount. 1. answer. What is going on? Remember to only use a good quality refined salt when adding salt to the water of your pool, cheap salt can stain your pool surface. As a last resort turn the power completely off and back on to give the electronics a chance to reboot. My viron salt chlorinator is reading low salt even after replacing almost 4 bags of pool salt. 1. Maximum Current (Amps) before shutdown Page 10 3. Firstly we must understand the process of salt water chlorination. The No Flow LED flashes for up to 60 seconds during startup. First, check power. However it did work for 24 hours and then stopped again with "no flow" The guys have rung ZODIAC for help and got no help at all. Your IP: 91.134.140.160 Please enable Cookies and reload the page. Doing this ensures excess calcium doesn’t become caked on the metallic plates. Solution: The Check Salt & Inspect Cell LEDs will flash at the same time when the salt level is between 2500-2600 ppm. The chlorine output goes up to two bars but no more and there doesn't appear to be any chlorine in the output water. The "cell on/off" button turns the cell on or off (funny that!) Algae is the most common cause of low or zero chlorine levels. No Flow Check Salt High Salt Inspect Cell Maximum Current (Amps) before shutdown T-Cell 3: 4.15 T-Cell 5: 6.40 T Cell 9: T Cell 15. Pentair IC40 Problems and Solutions. By checking and emptying both the skimmer basket (by the pool) and the pump basket (inside the pump) this will free up the water flow, allowing the system to fully ‘prime’ and function at full capacity. of operation, which is 3-5 years of service. my goldline control is showing "chlorinator off no flow". Check the following: cleaning the cell or the filter (see how to backwash a DE Filter or Clean a Cartridge Filter). At lower water temperatures, some generators can get lower salt readings. Speed two is a slower speed, and it may not be enough to trigger the flow switch in the salt cell to produce chlorine. Seek assistance from your local pool shop for the required procedure for your pool. Seek assistance from your local pool shop for the required procedure for your pool. My salt light won't go off but I have tested the level an its around 5,000 ppm. Please help. Chlorinator off- No flow message. The speeds that are programmed for speed 1, 2, 3, and 4 can be custom programmed to whatever speeds you’d want. I have checked my cells and they are clean, the Nano is not giving any errors or codes. Please reach out to us via LIVE CHAT to replace this if your product is still within warranty. My salt system says COLD. No answers. Try Note: Before you add a huge amount of salt, have a professional inspect your facility. The salt level is extremely low and your device is no longer releasing chlorine. Kindly check the following in an attempt to isolate the problem being experienced. Still having problems with your salt chlorinator not producing chlorine? The salt level light says it’s low. However, yesterday it replaced an aging and somewhat decripit Autochlor system. Recommend to customer to have water sample checked by dealer. 2. YES NO Add salt according to chart in Owner’s Manual. So could I just purchase a new salt chlorinator/Cell. The most common reason for low or no flow is that the baskets are full of debris. We bought an Autoclear salt water chlorinator off of Ebay. Share. What is going on? If you still have no luck check your skimmer, main drain and any possible obstructions. These quick and easy tips should ensure you avoid the most common salt water chlorinator problems. I have added fresh water to try to reduce salt level. If the chlorine level is dropping it might mean your salt chlorine generator is not producing enough chlorine. If your salt cell is plugged into an GFI outlet, make sure that the test button is not popped, or tripped. It's claimed that it's only 3 or so years old and is in good working order. Is the water temperature above 65˚? Remember less salt = less chlorine. Got Astral E25 salt chlorinator installed 4 months ago. YES NO Replace with correct cell. Reply. Is salt level 4000 ppm? If you are on a personal connection, like at home, you can run an anti-virus scan on your device to make sure it is not infected with malware. The chlorinator is not seeing the amps to the cell that it thinks it should. YES NO Is water temperature below 65° F? My Autochlor SM30 salt water chlorinator is showing a red flashing light indicating no water flow. Salt cells fail for a few different reasons, the main reason being lack of proper maintenance. Check the following: cleaning the cell or the filter (see how to backwash a DE Filter or Clean a Cartridge Filter). Moved into new house 6 months ago, got the pool guys to change few things including new salt chlorinator. Hi Ramsay, Salinity levels are measured via the conductivity of the water, one of the things that can affect that conductivity is temperature. Hi. Troubleshooting a Salt Chlorinator. Why is my Salt Generator Flashing ‘Check Salt’ and ‘Inspect Cell’ Together? Check for blockages. Like. Performance & security by Cloudflare, Please complete the security check to access. However, very often this concern is only triggered because the pool turned green or the water test shows zero free chlorine. This issue must be treated manually before a salt chlorinator can operate correctly. Salt water + electricity = chlorine gas, which you should be able to see bubbling off the plates in the chlorinator & also back into the pool via the return flow. Further, the "Low Salt" light is flashing. Reply. It goes from "no flow" to producing chlorine to "check salt level". The average salt cell life is around 5 years. Replace cell. Why Does my Filter Run at a High Filter Pressure and Have Reduced Water Flow to the Pool. That means that the Pentair IC40 life is running out – limited life remaining.Under proper operation, the intellichlor should provide at least 10,000 hrs. It is very important to check the cell regularly for excessive buildup. YES NO Add salt to compensate. I live in Brisbane, and as you probably know we had huge volumes of rain last Thursday and Friday, and the pool overflowed for a long time. Either take a reading from in your control panel if you have the easytouch, or use the test strips to verify your level is too high. Answer: Your salinity is a little higher than the recommended level which is between 2500 - 3500 ppm. The most common concern we get for salt system owners is that the the salt cell is not producing chlorine. Tracie says: June 2, 2017 at 5:15 PM. The Pool Boss | NJ's #1 In Ground Swimming Pool Company. Incorrect Salt Level (High or Low) Many chlorine generators will tell you by lights (like the Pentair Intellichlor shown a few photos below) or a numerical reading when salt level is low 1)Is the water temperature cold? salt level in the pool and the system may turn the chlorinator off. Still having problems with your salt chlorinator not producing chlorine? This also means that chlorine production has stopped. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. Check cell age, run time & output setting. Is unit wired 220V? Trace asked 1 year ago. 4. ; Salt level in pool water is less than 2,000 ppm: Check the salt level, and adjust as needed. Next make sure your pump is able to reach full prime. I slid the switch up and down, nothing but the power light on and the red no flow light on steady.....what do I do? The salt cell generator is fine. I have a Pentair Intellichlor 1C40 Power Center and a Pentair 1C40 Intellichlor Chlorine … Completing the CAPTCHA proves you are a human and gives you temporary access to the web property. Question: The salt level on my display says my pool is at 3900 ppm, and the stick is reading low free chlorine and total chlorine, as well as pH. We can be reached at the live chat located on this page during 9am-5pm Mon to Fri: https://www.astralpool.com.au/contact. Keeping your salt level up, at the proper level, and using stabilizer or conditioner, to shield the chlorine it produces from the sun, will reduce necessary run-time of your salt system. Strannik-au Swimming Pool Wizard Posts: 77 Joined: Fri 04 Apr, 2008 13:17 Location: Brisbane, Australia. Checked pool cleaner (old zodiac genie), seems ok, no … The fault lies in the powerboard and should be replaced. Replace the flow sensor. The reading dropped about 100 a week. Why does my Astral Pool Viron e Quilibrium Salt Chlorinator says low salt but when tested it shows a high reading, how do I solve this? Could this be possibly due to little or no salt in the pool? When you swim in it after a week of not shocking it, it feels like you’re swimming in lake water. Salt chlorinator Fitted 26-06-17 Would like to know coming up with check cell and low salt light on Does this mean that cell in no good after this short time because my pool is very small And is very well maintained. What do I need to do? If you are having problems with your chlorine generator, the first thing to do is to make sure you have enough salt in the pool water. I have removed the cell and it is not obstructed.My salt level is 3500ppm and I have been draining and adding fresh water to lower salt level, but it seems stuck on 3500. My unit is not toast I have done some diagnostic’s on my own( with no wiring diagrams since nobody seems to have them or share them) When the unit is in RUN mode the cell has 12 volts BUT when the code pops up with the low salt light the voltage drops to 0. The water passing over the cell should be cloudy. Check that the flow switch is plugged into the connector on the bottom of the control unit and that the wire is not cut or damaged. YES NO 3. Salt levels Use testing kits available in a local pool shop to test the salt levels of the pool. Solution 1. The easiest way to do this is to test your water balance regularly for the pH and chlorine levels. Like. The cell was replace about 9 months ago. Also clean your skimmer, pump, and perform a backwash or cleaning of your filter. My issue is the test water says I have NO chlorine, But that my Salt is around 4300, which is very high for the size of my pool(12,000 gallons). Pool temp is 69degrees. Fluidra Australia AstralPool 2 months ago. I am out of pocket at xmas $900 for a chlorinator, $250 a plumber , my 3 year old zodiac on ground that I expect is perfect, and still a green pool as there is "no flow" still. Post by Stressed but Happy, CA » Sat 13 Dec, 2008 14:34 . As with any electronic and mechanical systems, problems can occur. Few days ago, noted sign "no flow" on the screen. If you have no power reaching the salt cell, and the sensors (salt, temp, flow) are not causing an open circuit, something on the circuit board (resistors, capacitors and limiters) could be burned out or otherwise causing an open circuit (the problem lies where the power dies). AquaPure is a salt chlorine generating system used to sanitize your pool, using a closed-loop water-softening system. If your salt system is hardwired, variations in voltage could cause the controller to go a little haywire. It’s easy to understand why: owners are seeing that a reasonable up-front investment in a salt system, which converts ordinary table salt into pure chlorine, can lead to the end of their days of hauling chlorine bags around and constantly worrying about whether their pool is being properly sanitized. Now, when it runs, flat out on the output dial, at best it's reading 20% on the LEDs. What are the Recommended Water Chemistry Levels for my Pool? The Zodiac saltwater chlorinator will require about four thousand parts per million salt in the pool water. YES NO Chlorinator is working properly. Also, most system control units come with some kind of alert to notify you of low salt and chlorine … Matthew Simmons says: January 23, 2018 at 11:26 AM. Your chlorinator is a miniature liquid chlorine manufacturing plant. So could the cell now need replacing or is it something else. I have a 10000 gallon pool. A flashing LED indicates that the flow is restored, but there will be a 60 second delay before generation is re-established. Check for possible turbulence or obstructions inside of the flow T. Ensure there are at least 12 inches of straight pipe before the flow switch. 2. How can I tell if my salt water chlorinator is working properly? Signs That Your Salt Chlorinator Cell Is Not Working Sub-optimal chlorine levels in the water An LED signal indicating cell damage or overdue maintenance session. The most common reason for low or no flow is that the baskets are full of debris. Excessive sun exposure has evaporated chlorine: Use a pool cover when the pool is not in use. If you are at an office or shared network, you can ask the network administrator to run a scan across the network looking for misconfigured or infected devices. A salt chlorinator cannot produce enough chlorine to do this task. Recommend to customer to have water sample checked by dealer. Whatever your pool chlorine needs, AutoPilot ® can help! My test strips indicate the salt level is at 2500 ppm. I have cleaned the new cell and that doesn't seem to help. A dirty skimmer basket, clogged or dirty filter, and a clogged pump strainer, can cause insufficient water flow for the chlorinator to produce less chlorine. Why are my Salt Generator’s ‘Check Salt’ and ‘Inspect Cell’ Lights Staying On? We have people call us alot this time of year asking , "Why do you need to install a 3" floating chlorinator when I have a salt pool? Add salt according to chart in Owner’s Manual. The longer the salt system is operating, the more time it has to attract calcium salts. More often than not, the problem is with the salt cell and not the entire chlorinator system itself. I have a Zodiac LM2 series chlorinator. I have a Jandy Aquapure ei salt chlorinator. Your Zodiac chlorinator will indicate when salt is required, however to be sure you should take a water sample to your pool professional for testing. Number of swimmers has increased: Increase the daily operating time of the chlorinator. When you purchase a unit new, it should last several months without this problem coming up. - Answered by a verified Pool and Spa Expert. When these LEDs are ON, the salt level is 2300 ppm or below. My original T-15 cell was installed in Aug 2002 and died Sept 2006. More. Automatic chlorine generation is becoming more and more common in pools. Another way to prevent getting this page in the future is to use Privacy Pass. Again, dirty water is another reason behind the no flow sign. Cleaning your Salt Cell. The Hayward Aqua Rite Salt Chlorine Generator is hands-down the most popular residential salt chlorinator in the pool industry. The system is saying NO FLOW and Chlorinator is off despite being set at 95% and super chlorinate activated - It is as if my system is not recognizing the new cell was installed. There is nothing you need to do, other than waiting for the weather to warm up. Answer: Your salinity is a little higher than the recommended level which is between 2500 - 3500 ppm. So, check your salt level first. YES NO Have qualified electrician wire to 220V. It could be something as simple as a tennis ball stuck in your skimmer basket, or maybe your due for a new pump. so it is or isn't producing chlorine. There are so many reasons why your pool has little to no flow. Make sure you have at least 12" of straight pipe before the flow switch. Once those are done if your flow doesn’t turn green you have an issue with the cell itself. As a pump circulates the water through the generator, electrolysis plates ionize the salt to produce free chlorine. By checking and emptying both the skimmer basket (by the pool) and the pump basket (inside the pump) this will free up the water flow, allowing the system to fully ‘prime’ and function at full capacity. If your salt cell shows low flow, the first step is always to clean or backwash your filter. I unit is now reading low salt. 1. answer. Working well. I have removed the cell and it is not obstructed.My salt level is 3500ppm and I have been draining and adding fresh water to lower salt level, but it seems stuck on 3500. Share. Pool temp is 69degrees. Chlorine is still being produced when the lights are flashing. The Hayward Aqua Rite has sensed a no flow condition and has stopped generating chlorine. I got the manufacturer to send me a replacement (~$300) in Nov 2006 and now it crapped out too. Like. Understanding Salt Water Pools and Cold Water Temperatures. If the first couple aren’t strong enough, changing those to being a little stronger would be better. Is salt level 4000 ppm or higher? You may need to download version 2.0 now from the Chrome Web Store. We use cookies to give you the best possible experience on our website. Cloudflare Ray ID: 6373db46ac51b7e1 What is going on? Why is my Salt Generator Displaying ‘No Flow’? 13) For LM3 Models Insure LM3 is properly interfaced. When the water flow is not sufficient enough, then the light of no flow gets on. Chlorinator Off: Test Salt Level Message T-CELL-3 5.50 T-CELL-9 10.00 T-CELL-5 6.75 T-CELL-15 10.00 I’ve unplugged it and plugged it back it to no avail.
Doordash Walmart Tips,
Sweet Baby Ray's Bbq Sauce - Asda,
Boost Mobile Data Throttling Hack 2020,
Default Judgment Frcp,
Metaphors For Practice,
Marvel Silver Coins Tuvalu,
Getting Over It Softonic Android,